Diastolic left ventricular functional indices: Comparison between gated myocardial perfusion SPECT and echocardiography

Document Type : Original Article

Authors

1 Vascular and Endovascular Surgery Research Center, Mashhad University of Medical Sciences, Mashhad, Iran

2 Nuclear Medicine Research Center, Ghaem Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

3 Department of Radiology, Ghaem Hospital, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran

Abstract

Introduction: Many patients have only diastolic dysfunction without any abnormality in systolic function. We compared cardiac diastolic parameters obtained by gated myocardial perfusion SPECT (Gated SPECT) with those evaluated by echocardiography.
Methods: Forty-nine patients (aged 37-85 years, 19 males and 30 women) underwent Gated SPECT and echocardiography. Gated SPECT images were obtained with 16 frame/cardiac cycles. We derived the following diastolic indices: peak filling rate (PFR), time to PFR (TTPFR), mean filling rate in the first 1/3 of the diastole (MFR/3) and second filling rate (PFR2) due to left atrial contraction. In echocardiography we obtained the indices of ventricular filling: E wave, A wave, the E/A ratio, and the E wave deceleration time (DT) were considered. The LV isovolumic relaxation time (IVRT) was also determined.
Results:There was no significant correlation between echocardiographic findings and diastolic gated SPECT findings. Using Post-Hoc One-way analysis significant difference was seen only in MFR/3 between diastolic dysfunction groups (P value=0.02). There was no significant difference in other diastolic gated SPECT variables in these groups.
Conclusion: Diastolic parameters obtained from 16-frame/cardiac cycle gated SPECT didn’t correlate with echocardiographic indices.

Keywords

Main Subjects


  1. Nakae I, Matsuo S, Koh T, Mitsunami K, Horie M. Left ventricular systolic/diastolic function evaluated by quantitative ECG-gated SPECT: comparison with echocardiography and plasma BNP analysis. Ann Nucl Med. 2005 Sep;19(6):447-54.
  2. Yamano T, Nakamura T, Sakamoto K, Hikosaka T, Zen K, Nakamura T, Sawada T, Azuma A, Nishimura T, Nakagawa M. Assessment of left ventricular diastolic function by gated single-photon emission tomography: comparison with Doppler echocardiography. Eur J Nucl Med Mol Imaging. 2003 Nov;30(11):1532-7.
  3. Sadeghi R , Dabbagh Kakhki VR , Zakavi SR , Emadzadeh MR , Torabian-Kakhki M , Shafizadeh N. Gated 99mTc-MIBI myocardial perfusion SPECT in patients with right bundle branch block but without evidence of coronary artery disease. Iran J Nucl Med. 2013;21(2):60-64.
  4. Vasan RS, Levy D. Defining diastolic heart failure: a call for standardized diagnostic criteria. Circulation. 2000 May 2;101(17):2118-21.
  5. Kikkawa M, Nakamura T, Sakamoto K, Sugihara H, Azuma A, Sawada T, Okuyama C, Ushijima Y, Nishimura T. Assessment of left ventricular diastolic function from quantitative electrocardiographic-gated 99mTc-tetrofosmin myocardial SPET. Eur J Nucl Med. 2001 May;28(5):593-601.
  6. Dabbagh Kakhki VR , Eshraghi A , Ayati N , Vojdanparast M , Sadeghi R , Rezvani Khorashad A. Nicorandil effect on myocardial perfusion in patients with slow coronary flow phenomenon assessment by gated myocardial perfusion SPECT. Iran J Nucl Med. 2017;25(1):60-65.
  7. Williams KA, Taillon LA. Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion images. Comparison with assessment by contrast ventriculography and first-pass radionuclide angiography. J Am Coll Cardiol. 1996 Jan;27(1):173-81.
  8. Dabbagh Kakhki VR, Zakavi SR, Sadeghi R, Emadzadeh MR, Vejdani A. Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT. Iran J Nucl Med. 2008;16(1):14-19.
  9. Dabbagh Kakhki VR, Fazli Nezhad A, Zakavi SR, Rahmani E, Sadeghi R, Ayati N. Echocardiographic left ventricular functional changes in acute hypothyroidism vs. subclinical hyperthyroidism in patients with differentiated thyroid carcinoma. Iran J Nucl Med. 2011;19(2):28-37.
  10. Fallahi B, Beiki D, Salehi Y, Emami-Ardekani A, Fard-Esfahani A, Aghahosseini F, Haghighatafshar M, Eftekhari M. Reverse perfusion pattern in myocardial perfusion imaging using technetium-99m-sestamibi in patients with intermediate risk for coronary artery disease in relation to the time of acquisition and intensity of visceral uptake as artifactual causes. Nucl Med Commun. 2017 Jan;38(1):15-20.
  11. Danesh-Sani SH, Zakavi SR, Oskoueian L, Kakhki VR. Comparison between 99mTc-sestamibi gated myocardial perfusion SPECT and echocardiography in assessment of left ventricular volumes and ejection fraction--effect of perfusion defect and small heart. Nucl Med Rev Cent East Eur. 2014;17(2):70-4.
  12. Lenihan DJ, Gerson MC, Hoit BD, Walsh RA. Mechanisms, diagnosis, and treatment of diastolic heart failure. Am Heart J. 1995 Jul;130(1):153-66.
  13. Spirito P, Maron BJ, Bonow RO. Noninvasive assessment of left ventricular diastolic function: comparative analysis of Doppler echocardiographic and radionuclide angiographic techniques. J Am Coll Cardiol. 1986 Mar;7(3):518-26.
  14. Rokey R, Kuo LC, Zoghbi WA, Limacher MC, Quinones MA. Determination of parameters of left ventricular diastolic filling with pulsed Doppler echocardiography: comparison with cineangiography. Circulation. 1985 Mar;71(3):543-50.
  15. Nakajima K, Taki J, Kawano M, Higuchi T, Sato S, Nishijima C, Takehara K, Tonami N. Diastolic dysfunction in patients with systemic sclerosis detected by gated myocardial perfusion SPECT: an early sign of cardiac involvement. J Nucl Med. 2001 Feb;42(2):183-8.